Industrial dry-type transformers, built in Dandenong South since 1977 5-year warranty Lead time guarantee

3ph 690V to 415V Isolation Transformers

690V is the standard output of most grid-scale battery inverters, and it’s common on large drives and mining installations. Almost nothing you need to run alongside that equipment works at 690 V.

Thermal management, fire detection and suppression, controls and SCADA, lighting, small power, comms, security, pumps — all of it is 415 V and 240 V equipment. Something has to bridge the two, and on a site where the auxiliary system is what keeps the main asset alive, that something should not be an afterthought.

The SD690 range is a three-phase dry-type isolation transformer that cleanly converts 690V to 415V four-wire supply with a neutral.

southern-transformers-150kva-3ph-isolation-transformer. two transformers, front one has top and front/back panels removed showing the transformer. the back one has panels fitted, showcasing the IP23 enclosure

Below is a reference table of standard sizes, typically requested by customers. Other kVA ratings available on request.

SD690 standard range — three-phase dry-type 690 V to 415 V isolation transformers for auxiliary supplies on battery storage, inverter-fed and mining installations. Dyn11, with a neutral available on the 415 V output. 50 kVA to 750 kVA, and custom kVA ratings built to order. Dimensions and mass for both IP23 indoor and IP65 outdoor enclosures are in each unit’s specs. Air-forced (AF) cooling is available where space is limited and can reduce the footprint noticeably — ask when you enquire.
Part numberRatingInputOutputConfigurationSpecifications
SD690-50kVA-3I50 kVA690 V @ 41.8 A415 V @ 69.6 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-100kVA-3I100 kVA690 V @ 83.7 A415 V @ 139 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-150kVA-3I150 kVA690 V @ 126 A415 V @ 209 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-200kVA-3I200 kVA690 V @ 167 A415 V @ 278 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-250kVA-3I250 kVA690 V @ 209 A415 V @ 348 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-300kVA-3I300 kVA690 V @ 251 A415 V @ 417 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-400kVA-3I400 kVA690 V @ 335 A415 V @ 556 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-500kVA-3I500 kVA690 V @ 418 A415 V @ 696 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-600kVA-3I600 kVA690 V @ 502 A415 V @ 835 ADyn11 3-wire Delta / 4-wire StarOther available on request
SD690-750kVA-3I750 kVA690 V @ 628 A415 V @ 1043 ADyn11 3-wire Delta / 4-wire StarOther available on request

Beyond what’s in the above table

Each unit’s specs give you the dimensions, approx. mass, configuration, construction and standards. These apply across the range:

Frequency: 50 Hz or 60 Hz
Impedance: 2–4% Ez typical, or designed to a specified value
K-factor: K4 typical, higher for heavily non-linear loads
Cooling: Air natural (AN). Air forced (AF) available where the footprint has to come down
Temperature rise: <125 °C at 45 °C ambient
Ambient Temperature:  −10 °C to 45 °C

Enclosures:

  • IP23 vented steel for switchrooms and containerised plant.
  • IP65 sealed steel on heavy-duty galvanised plinths for units sitting on a pad in the open.
  • Open (IP00) where the transformer goes inside your own enclosure or skid.

Most battery storage auxiliary transformers end up IP65 or inside the existing containerised plant.

Custom ratings: The table is an excerpt of our standard range. If your auxiliary 690V to 415V load doesn’t land on one of those numbers, we build to it — custom transformer solutions.

 

 

 

 

200kVA isolation transformers fitted in IP65 with wiring chambers on sides of main enclosure. one transformer has front panel removed, showing transformer inside. units are sitting on driveway of Southern Transformers at 8 superior drive dandenong south

What we need to quote

  • Auxiliary load in kVA, or the connected equipment list
  • Whether the 690V source is an inverter, a generator or a supply transformer
  • Indoor, containerised, or outdoors on a pad
  • Ambient temperature range, and altitude if above 1,000 m
  • Space available, and how the unit gets into position
  • Any specified impedance, vector group or project standards

If you only have a single line 690V to 415V and a site address, send that. Working the rest out is our job.

Enclosures for Your Three-Phase Transformer

Southern Transformers can supply your transformer open, or encase your three-phase transformer in an oyster grey powder-coated steel enclosure for hard wiring. Our standard enclosures are rated at IP23 (indoor), or IP65 (outdoor) for when more protection is necessary. Outdoor enclosures typically come with wiring chambers fitted to the side to house input/output terminals.
Check this useful IP rating table.

We also offer wall-mounted enclosures for smaller 3-phase isolation transformers up to about 5kVA.

Frequently Asked Questions

If you have a question that is not listed here, please contact us – we’re always happy to help.