3ph 415V / 380V step down transformer
Convert Australian 3-phase power (415VAC) to 3-phase voltage (380VAC) with a 3-phase step-down Auto-transformer.
Ideal for running 3-phase equipment in Australia brought in from Europe, China or Korea, or other countries with 380V power.
Note: Our step-down transformers are autotransformers and do not provide galvanic isolation. If your application requires electrical isolation for safety or compliance, please see our 3-Phase Isolation Transformers or contact us to discuss your requirements.
Find & Select the most suitable size for your 380V-rated equipment below.
| Part number | Rating | Suits equipment up to | Input | Output | Specifications |
|---|---|---|---|---|---|
| SD380-1kVA-3A | 1 kVA | 0.8 kW | 415 V @ 1.4A | 380 V @ 1.5A | |
Part numberSD380-1kVA-3A Power1 kVA · 0.8 kW at 0.8 pf Input3-phase 415 V @ 1.4A Output3-phase 380 V @ 1.5A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D230 × 300 × 225 mm700 × 400 × 400 mm Mass13 kg41 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-3kVA-3A | 3 kVA | 2.4 kW | 415 V @ 2.8A | 380 V @ 4.5A | |
Part numberSD380-3kVA-3A Power3 kVA · 2.4 kW at 0.8 pf Input3-phase 415 V @ 2.8A Output3-phase 380 V @ 4.5A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D230 × 300 × 225 mm700 × 400 × 400 mm Mass16 kg42 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-5kVA-3A | 5 kVA | 4 kW | 415 V @ 7A | 380 V @ 8A | |
Part numberSD380-5kVA-3A Power5 kVA · 4 kW at 0.8 pf Input3-phase 415 V @ 7A Output3-phase 380 V @ 8A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D230 × 300 × 225 mm700 × 400 × 400 mm Mass17 kg44 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-8kVA-3A | 8 kVA | 6.4 kW | 415 V @ 11A | 380 V @ 12A | |
Part numberSD380-8kVA-3A Power8 kVA · 6.4 kW at 0.8 pf Input3-phase 415 V @ 11A Output3-phase 380 V @ 12A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D280 × 300 × 280 mm700 × 400 × 400 mm Mass20 kg44 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-10kVA-3A | 10 kVA | 8 kW | 415 V @ 14A | 380 V @ 15A | |
Part numberSD380-10kVA-3A Power10 kVA · 8 kW at 0.8 pf Input3-phase 415 V @ 14A Output3-phase 380 V @ 15A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D280 × 300 × 280 mm700 × 400 × 400 mm Mass20 kg54 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-12kVA-3A | 12 kVA | 9.6 kW | 415 V @ 17A | 380 V @ 18A | |
Part numberSD380-12kVA-3A Power12 kVA · 9.6 kW at 0.8 pf Input3-phase 415 V @ 17A Output3-phase 380 V @ 18A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D280 × 300 × 280 mm700 × 400 × 400 mm Mass20 kg54 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-15kVA-3A | 15 kVA | 12 kW | 415 V @ 21A | 380 V @ 23A | |
Part numberSD380-15kVA-3A Power15 kVA · 12 kW at 0.8 pf Input3-phase 415 V @ 21A Output3-phase 380 V @ 23A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D280 × 300 × 280 mm700 × 400 × 400 mm Mass26 kg54 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-20kVA-3A | 20 kVA | 16 kW | 415 V @ 28A | 380 V @ 30A | |
Part numberSD380-20kVA-3A Power20 kVA · 16 kW at 0.8 pf Input3-phase 415 V @ 28A Output3-phase 380 V @ 30A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D280 × 300 × 280 mm700 × 400 × 400 mm Mass30 kg56 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-25kVA-3A | 25 kVA | 20 kW | 415 V @ 35A | 380 V @ 38A | |
Part numberSD380-25kVA-3A Power25 kVA · 20 kW at 0.8 pf Input3-phase 415 V @ 35A Output3-phase 380 V @ 38A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D280 × 300 × 280 mm700 × 400 × 400 mm Mass32 kg69 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-30kVA-3A | 30 kVA | 24 kW | 415 V @ 42A | 380 V @ 46A | |
Part numberSD380-30kVA-3A Power30 kVA · 24 kW at 0.8 pf Input3-phase 415 V @ 42A Output3-phase 380 V @ 46A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D280 × 300 × 280 mm700 × 400 × 400 mm Mass34 kg69 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-40kVA-3A | 40 kVA | 32 kW | 415 V @ 56A | 380 V @ 60A | |
Part numberSD380-40kVA-3A Power40 kVA · 32 kW at 0.8 pf Input3-phase 415 V @ 56A Output3-phase 380 V @ 60A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D370 × 450 × 270 mm700 × 400 × 400 mm Mass50 kg75 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-50kVA-3A | 50 kVA | 40 kW | 415 V @ 70A | 380 V @ 76A | |
Part numberSD380-50kVA-3A Power50 kVA · 40 kW at 0.8 pf Input3-phase 415 V @ 70A Output3-phase 380 V @ 76A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D370 × 450 × 270 mm700 × 600 × 400 mm Mass56 kg95 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-60kVA-3A | 60 kVA | 48 kW | 415 V @ 84A | 380 V @ 91A | |
Part numberSD380-60kVA-3A Power60 kVA · 48 kW at 0.8 pf Input3-phase 415 V @ 84A Output3-phase 380 V @ 91A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D480 × 480 × 480 mm700 × 600 × 400 mm Mass86 kg95 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-75kVA-3A | 75 kVA | 60 kW | 415 V @ 104A | 380 V @ 114A | |
Part numberSD380-75kVA-3A Power75 kVA · 60 kW at 0.8 pf Input3-phase 415 V @ 104A Output3-phase 380 V @ 114A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D480 × 480 × 480 mm700 × 600 × 400 mm Mass91 kg125 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-100kVA-3A | 100 kVA | 80 kW | 415 V @ 139A | 380 V @ 152A | |
Part numberSD380-100kVA-3A Power100 kVA · 80 kW at 0.8 pf Input3-phase 415 V @ 139A Output3-phase 380 V @ 152A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D685 × 480 × 390 mm700 × 600 × 400 mm Mass125 kg115 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-125kVA-3A | 125 kVA | 100 kW | 415 V @ 174A | 380 V @ 174A | |
Part numberSD380-125kVA-3A Power125 kVA · 100 kW at 0.8 pf Input3-phase 415 V @ 174A Output3-phase 380 V @ 174A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D685 × 480 × 390 mm900 × 800 × 400 mm Mass115 kg220 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-150kVA-3A | 150 kVA | 120 kW | 415 V @ 209A | 380 V @ 228A | |
Part numberSD380-150kVA-3A Power150 kVA · 120 kW at 0.8 pf Input3-phase 415 V @ 209A Output3-phase 380 V @ 228A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D685 × 480 × 480 mm900 × 800 × 400 mm Mass158 kg220 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-200kVA-3A | 200 kVA | 160 kW | 415 V @ 278A | 380 V @ 304A | |
Part numberSD380-200kVA-3A Power200 kVA · 160 kW at 0.8 pf Input3-phase 415 V @ 278A Output3-phase 380 V @ 304A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D700 × 710 × 480 mm1100 × 800 × 400 mm Mass220 kg245 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-250kVA-3A | 250 kVA | 200 kW | 415 V @ 348A | 380 V @ 380A | |
Part numberSD380-250kVA-3A Power250 kVA · 200 kW at 0.8 pf Input3-phase 415 V @ 348A Output3-phase 380 V @ 380A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D700 × 710 × 480 mm1500 × 950 × 750 mm Mass240 kg413 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-350kVA-3A | 350 kVA | 280 kW | 415 V @ 487A | 380 V @ 532A | |
Part numberSD380-350kVA-3A Power350 kVA · 280 kW at 0.8 pf Input3-phase 415 V @ 487A Output3-phase 380 V @ 532A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D1080 × 760 × 660 mm1500 × 950 × 750 mm Mass362 kg513 kg Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
| SD380-500kVA-3A | 500 kVA | 400 kW | 415 V @ 696A | 380 V @ 760A | |
Part numberSD380-500kVA-3A Power500 kVA · 400 kW at 0.8 pf Input3-phase 415 V @ 696A Output3-phase 380 V @ 760A EnclosureIP23 indoorIP65 outdoor Dimensions H × W × D1080 × 760 × 660 mmOn request Mass462 kgOn request Also available open-type (IP00). We quote indoor and outdoor together so you can compare size and price before you decide. Construction. Three-phase auto-transformer with screw terminals on top for input and output. Brass earth stud provided for connection. Neutrals available for connection if required. Supplied open (IP00), or fitted inside a powder-coated vented steel enclosure for indoor (IP23) or outdoor (IP65) use, with panels to access terminals for hardwiring. Warranty5 years standard StandardsAS/NZS 60076 AS/NZS 61558 Lead Time GuaranteeConfirmed on order Australian madeBuilt in Dandenong South Sends the part number and rating with your enquiry. | |||||
Frequently Asked Questions
If you have a question that is not listed here, please contact us – we’re always happy to help.
It’s commonly used to operate European, Korean or Chinese 380V equipment on Australian 415V mains supply safely and reliably.
Read down the “Suits equipment up to” column and take the first row that covers your figure. A 20 kW machine lands on the 25 kVA unit. The conversion already assumes 0.8 power factor, which is the worst case for this kind of load, so you do not need to know your own power factor to use the table. If the plate also shows a starting or inrush current, tell us — motor and drive loads sometimes want the next size up.
Yes. The dimensions and mass in the table are for the IP23 indoor enclosure, which is what most installations use. Open-type (IP00) and IP65 outdoor versions are both available — the dimensions and mass differ, so ask for the figures when you enquire and we will include them in the quote.
Yes. The standard SD220 range is autotransformers, which is what keeps them compact and quick to build — they share one winding, so there is no galvanic separation between input and output. If you need the voltage changed and the two sides electrically separate, we build that as a custom engineered isolation transformer. It is routine work, not an exception. Tell us the voltage pair and the rating and we will quote it.
We keep stock of the most commonly required sizes — 10 kVA, 25 kVA and 50 kVA. Everything else is built to order in our Dandenong South factory.
Lead time depends on the unit and on how the workshop is loaded, so we give you a realistic estimate with your quote rather than a number chosen to sound good. When you place the order we commit to a completion date — and we stand behind that date with our Lead Time Guarantee: if we miss it, you receive a credit of up to 20% of the order value.
Generally yes. Confirm nameplate ratings and any derating if frequency differs between regions.
Yes, but typically these are not required on these stepdown transformers, as the equipment they are used on typically have a voltage tolerance, and not required.
We can include ±2.5% & ±5% off-load taps (or as specified) for fine voltage adjustment if required.
Australian-Made. Built to Last
All Southern Transformers products are locally designed and manufactured for long service life, with full compliance to Australian Standards.
Custom-Built for Industrial Demands
From commercial industries to major sectors, we tailor each transformer to meet the real-world needs of your application – no limitations.
Delivered to Your Schedule without Compromise
We understand project timelines matter – Southern Transformers delivers transformers to meet your schedule, fast or slow, without cutting corners.
5-year Warranty, 25+ year design life
Every transformer is designed and built to operate continuously at rated power for 25+ years, backed by an industry-leading standard 5-year warranty.
We combine industry expertise with direct technical support, because we don’t take the trust you place in us lightly
Every transformer we build supports critical infrastructure — from mining operations, to data centres and industrial facilities.
We appreciate the pressure around compliance, lead times, and performance, and understand that transformer specifications are somewhat foreign to many.
That’s why we work closely with you from first enquiry through to delivery, ensuring the right design, the right specification, and long-term reliability.


Transformer Solutions Made Simple
Provide your project details and we’ll respond promptly with expert guidance tailored to your needs.
Transformer Solutions Made Simple
Provide your project details and we’ll respond promptly with expert guidance tailored to your needs.